Product Description
Product Description
The Opus XCM 20R functions as an open Building Automation System (BAS) network manager that combines integrated control, supervision, data logging, alarming, and scheduling into a single controller platform. The XCM 20R is designed to integrate diverse devices into a seamless system, as it supports a wide range of open protocols, including BACnet®, MODBUS® and LonWorks®. The XCM 20R also supports NovarNet protocol and is backward compatible with most Novar Logic One and Spectrum field controllers.
Application
Application
BAS supervisory control for HVAC, lighting and energy management applications within large buildings. The XCM.20R is ideal for applications that require a local touch screen user interface and inputs/outputs that are centrally located with the Executive Controller. The XCM20R includes an integrated enclosure and is compatible with legacy Logic One EnvoiXE, EP2 and all Lingo baseplates, making upgrades easy.
Specifications
Specifications
Mounting
Compatible with the following surface mounted baseplates:
- XCM 20R (new installations)
- EP2, Lingo
- Lingo XE
- Envoy XE
Dimensions
- Height: 13 inches
- Width: 12.5 inches
- Depth: 2.0 inches
Power Requirements
- Input: 24 VAC, Class 2 (22 to 28 VAC),
- Frequency: 50/60 Hz
- Consumption: 40 VA
- Protection: all inputs/outputs protected against high voltage surge and transients
Inputs
8 Universal
- Thermistor: Type 3, 10K 14 to 212 F
- Voltage: 0-10VDC, input impedance >5K ohms
- Current: 4-20mA, input impedance >5Kohms, loop source 20-24VDC
- Digital: contact closure or pulse, open circuit voltage 5VDC, dry contact wetting current 4mA, max pulse count frequency 20Hz @ 50% duty cycle
Outputs
- 4 Digital:
- 24VAC or DC, 2 amps, Class 2 SPDT relay outputs
Diagnostics
- 5 integrated diagnostic points for monitoring internal and external power supplies, system ambient temperature and transformer ground fault status
Communications
6 RS-485 Ports (non isolated; optimized failsafe biasing provided on all ports)
Application Protocol
- NovarNet : 1.7-9.6 kBd (biasing may be required)
- BACnet MSTP: max 76.8 Kbps
- Modbus RTU: 38.4 Kbps
- 1 (Optional) LonWorks Port using additional optional card: max 76.8 kbps
- 1 RS-232 Port: 9-pin D-shell connector for serial shell mode access
- 2 Ethernet Ports: 10/100 Mbps
Application Protocol
- BACnet IP
- Modbus TCP
- Niagara Network (Fox)
- oBix
LED Indicators
- Output
- Power
- Module Communications
- Network Communications
Operating Environment
- Temperature: 32°F to 122°F (0°C to 50°C)
- Humidity: 10 to 90% Relative, non-condensing
Approvals
- Listed device: CUL/UL E90949; UL R/C E134292
- Standards used: Module is UL listed as PAZX and PAZX7 per UL916 and also UL Recognized Component as SDFY2 and SDFY8 per UL 873, “Signal Equipment”, CE, FCC Part 15, Class A
- International:CE, C-Tick, and WEEE
Application Requirements
- Opus Version 5.5 or higher
- Application Version 4.0 or higher
- Xcm20Rio.jar version 1.1 or higher
Product Order Numbers
Product Order Numbers
Name | Product Description | Order Number |
XCM20R-RC-C |
RC Base Cover |
XCM20R-RC-C |
XCM20R-EP2-C |
EP/2 Cover |
XCM20R-EP2-C |
XCM20R-LINGO-C |
Lingo Cover |
XCM20R-LINGO-C |
XCM20R-LXE-C |
Lingo XE Cover |
XCM20R-LXE-C |
XCM20R-BPL-C |
XCM20R Base Cover |
XCM20R-BPL-C |
XCM20R-BPL |
XCM20R Base (includes transition board and cover) |
XCM20R-BPL |
XCM20R-BPL-TRAN |
XCM20 BPL Transition board |
XCM20R-BPL-TRAN |
XCM20R-RC-KIT |
RC Upgrade Kit (includes adaptor board and RC cover) |
XCM20R-RC-KIT |
XCM20R-RC-ADP |
RC upgrade adaptor board |
XCM20R-RC-ADP |
XCM20R-C-BFU |
Color display, BACnet, FOX, UI |
XCM20R-C-BFU |
XCM20R-C-BFUM |
Color display, BACnet, FOX, UI, Modbus |
XCM20R-C-BFUM |
XCM20R-C-BFUMI |
Color display, BACnet, FOX, UI, Modbus & Modbus TCP |
XCM20R-C-BFUMI |
XCM20R-C-BLFU |
Color display, BACnet, Lon, FOX, UI |
XCM20R-C-BLFU |
XCM20R-C-BLFUM |
Color display, BACnet, Lon, FOX, UI, Modbus |
XCM20R-C-BLFUM |
XCM20R-C-BLFUMI |
Color display, BACnet, Lon, FOX, UI, Modbus & Modbus TCP |
XCM20R-C-BLFUMI |
XCM Battery |
Replacement Battery for all XCMs |
NPB-BATT |