    The Opus XCM10S functions as an open Building Automation System (BAS) network manager that combines integrated control, supervision, data logging, alarming, and scheduling into a single controller platform. The XCM10S is designed to integrate diverse devices into a seamless system, as it supports  BACnet® and MODBUS® open protocols. The XCM10S also supports NovarNet protocol and is backward compatible with most Novar Logic One and Spectrum field controllers.

    acrobatjpgDownload xcm.10S Sell Sheet Here

     

  • Application

    BAS supervisory control for HVAC, light-ing and energy management applications for small to medium sized buildings. The XCM10S includes an integrated enclosure and is ideal for applications that require a high mix of inputs and outputs that are centrally located with the Executive controller. In addition, the XCM10S is compatible with legacy Logic One Savvy and EC baseplates, making upgrades easy.

  • Specifications

    Mounting
    • Compatible with EC and Savvy surface mounted baseplates
    Dimensions (electronics and baseplates)
    • Height: 30 inches
    • Width: 13.25 inches
    • Depth: 2.5 inches
    Power Requirements
    • Input: 24 VAC, Class 2 (22 to 30 VAC)
    • Frequency: 50/60 Hz
    • Consumption: 40 VA
    • Protection: all inputs/outputs protected against high voltage surge and transients
    Inputs
    • 8 Universal
      • Thermistor: Type 3, 10K -10 to 135 F
      • - Voltage: 0-10VDC, input impedance >5K ohms 
      • Current: 0-20mA (switch selectable) 
      • Digital: contact closure only, 300uA wetting current3 Analog: 4-20mA (loop source 24VDC @ 500mA max)
    • 2 Digital contact closure only
    • 8 Timed Override: for use with Novar 8-button override panel
    Output
    • 8 Relay: 24VAC or VDC, 2 amp pilot duty Class 2
    • 1 System Fault: 24VAC or VDC, 2 amp pilot duty Class 2
      Communications
    • 2 RS-485 Ports (non isolated) 
      • Application Protocol 
      • NovarNet : 1.7-9.6 kBd (biasing may be required) 
      • BACnet MSTP: max 76.8 Kbps 
      • Modbus RTU: 38.4 Kbps
    • 1 RS-232 Port: 9-pin D-shell connector for serial shell mode access
    • 2 Ethernet Ports: 10/100 Mbps 
      • Application Protocol 
      • BACnet IP 
      • Modbus TCP 
      • Niagara Network (Fox) 
      • oBIXLED 
    Indicators
    • Output
    • Power
    • Module Communications
    • Network Communications
    Operating Environment
    • Temperature: 32°F to 122°F (0°C to 50°C)
    • Humidity: 0 to 95% Relative, non-condensing
    Approvals
    • Listed device: CUL/UL E90949
    • Standards used: UL 916, Energy Management Equipment CSA C22.2, No. 205-M1983
    Application Requirements
    • Opus Version 5.5 or higher
    • Application Version 4.0 or higher
  • NameProduct DescriptionOrder Number
    XCM 10S Opus Executive Controller XCM10S-B-F-U-MB
    HOA Lock-Out Bracket Kit XCM10S-HL-KIT
    Baseplate XCM Mounting Base 751100000XCM
    Battery Replacement Battery for all XCMs NPB-BATT